The CDV-700RP probe is specifically designed to have greater
sensitivity and easily replace the existing beta/gamma probe
on the CDV-700 survey meter. The grip on the probe is adjustable
to allow for the perfect fit to Victoreen or Lionel meters.
Just unplug the existing probe and plug in the CDV-700RP.
(For use with CDV-700 meters only).
Specifications
Detector
Type - GM tube with thin mica window. Effective
Diameter: 1.75 inches (45 mm). Window Thickness:
1.4-2.0 mg/cm2 Efficiencies
Gamma - 3600 CPM/mR/hr; beta - C-14 10%, S-90/Y-90
35% Probe construction
Anodized aluminum housing. Size - Approx. length:
22.2 cm (8.75 in.) Dia.: 7.0 cm (2.75 in.). Connector
- To match either Victoreen or Lionel CDV-700 meters.
Handle - adjustable Black vinyl grip. Operating Voltage
850 - 1000 volts - 900 volts optimum Temperature Range
-25°C to 50°C (-13°F to 122°F) Humidity Range
0 - 90% Relative Humidity Weight
Approx. 328 grams (11.5 oz.) without cable. Includes
Protective cap for the detector. Warranty
One year limited warranty
RADIATION
ALERT® Quality Handheld
Radiation Detectors, Geiger Counter, & Radiation Spectrum Analyzers
are engineered to be reliable,
simple to use, affordable and made
in the USA. For ordering and pricing,
Call 1-800-293-5759.