MODEL

RADIATION DETECTED

a ß y x
a ß y x
a ß y x
a ß y x

a ß y x

y x

DISPLAY

digital readout
digital readout

digital readout

dual scale analog meter

dual scale analog meter

Dual Analog scale, uSv and
mR analog meter

DETECTOR GEIGER MUELLER

Halogen-quenched uncompensated
with thin mica window 1.4-2.0 mg/cm2 thick. Effective diameter
1.75/45mm
Halogen-quenched uncompensated
with thin mica window 1.5-2.0 mg/cm2 thick. Effective diameter
.36/.92cm

 Halogen-quenched uncompensated
with thin mica window 1.4-2.0 mg/cm2 thick. Effective diameter
1.75/45mm
Halogen-quenched uncompensated
with thin mica window 1.5-2.0 mg/cm2 thick. Effective diameter
.36/.92cm
Halogen quenched Energy
compensated with thin mica window 1.5-2.0 mg/cm2 thick. Effective
diameter .36/.92cm.

Halogen quenched

energy compensated

Probe Type
Internal
External

Internal

Internal

Internal

Internal

GAMMA SENSITIVITY

Referenced to
Cs-137

3500 CPM/mR/hr
Referenced to Cs-137
3500 CPM/mR/hr
Referenced to Cs-137

3500 CPM/mR/hr
Referenced to Cs-137

1000 CPM/mR/hr

1000 CPM/mR/hr
Offers a more accurate linear reading for gamma and X-rays between 40-100
keV
416 CPM/mR/hr

OPERATION RANGE

Autoranging
mR/hr .001 to 100
CPM 0 to 300,000
mSv/hr .01 to 1000
Total Counts 9,999,000
Autoranging
mR/hr .001 to 100
CPM 0 to 300,000
mSv/hr .01 to 1000
Total Counts 9,999,000

Autoranging
mR/hr .001 to 100
CPM 0 to 300,000
mSv/hr .01 to 1000
Total Counts 9,999,000

Over 3 selectable ranges
mR/hr 0 to 50
CPM 0 to 50,000
or mSv/hr 0 to 500

Over 3 selectable ranges
mR/hr 0 to 50
CPM 0 to 50,000
or mSv/hr 0 to 500

Over 4 selectable ranges
mR/hr 0 to 1000
.001 to 10 mSv/hr

ADJUSTABLE ALARM

yes
yes

yes

ACCURACY

 15% of full scale
15% of full scale
 15% of full scale

15% of full scale

15% of full scale

15% of full scale

AUDIO

Can be switched off for silent
operation
Can be switched off for
silent operation
Can be switched off for
silent operation
Can be switched off for
silent operation
Can be switched off for
silent operation
Can be switched off for
silent operation

POWER REQUIREMENTS

1 nine volt battery
1 nine volt battery

1 nine volt battery

1 nine volt battery

1 nine volt battery

1 nine volt battery

TEMPERATURE RANGE

-10° to +50°C (14° to 122°F)

BATTERY LIFE @ Background

2000 Hours
2000 Hours

2000 Hours

2000 Hours

2000 Hours

2000 Hours

WEIGHT

291g (0.64 lbs.)
570 g (1.25 lbs.)

217 g (7.7 oz.)

178 grams/6.3 oz.

198.1 grams/7 oz.

188 grams/6.4 oz.

SIZE

140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.)
Base Unit: 140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.)
Probe: 260 X 70 X 25 mm (10.25 X 2.75 X 1 in.)
Cable length 3′

276 x 44 x 64 mm (10.88 x 1.75 x 2.5 in.)

145 x 72 x 38mm
5.7 x 2.8 x 1.5 in.

145 x 72 x 38mm
5.7 x 2.8 x 1.5 in.

145 x 72 x 38mm
5.7 x 2.8 x 1.5 in.

WARRANTY

1 year limited/90 days on
detector
1 year limited/90 days on
detector

1 year limited/90 days on
detector

1 year limited

1 year limited

1 year limited

INCLUDES

Carrying case
Carrying case

Carrying case

Carrying case

Carrying case

Carrying case

CE MARK

yes

yes

yes

yes

yes

yes