product image

NuCoMo 100

NuCoMo-100

Contamination monitor for high background radiations

Locations with a high background radiation – such as certain areas of nuclear power plants or sites of nuclear incidents – prohibit the use of most contamination measurement devices, while at the same time the risk of having contaminated surfaces is increased. This challenging task is where the newly developed NuCoMo-100 excels.

With the NuCoMo-100, β-contamination can be detected in a gamma background of up to 40 μSv/h when all the other standard contamination monitors are saturated with gamma counts. Most of all the user-friendly, handheld device allows to monitor significant contamination early-on and considerably mitigate the risk of dispersing radioactivity over the site.

The NuCoMo-100 has been developed as part of the collaborative R&D efforts with the CEA LIST. It uses a phoswich detector together with an innovative algorithm. Each scintillator of the phoswich has a different decay time constant allowing to perform
Pulse Shape Discrimination (PSD) between the beta and gamma pulses. Hence this state-of-the-art detector enables to discriminate the γ-background and measure only the β-contamination on the surface by comparing signals from two different detector layers. The user can choose between displaying the measurement results in cps, Bq, and Bq/cm². The possibility for expert users to additionally display either a histogram of the last 100s or a bar diagram of the current value in percent of the
alarm threshold increases the usability further. Two separate alarm thresholds can be set. The LED-ring flashes in yellow or red accordingly. Alarm thresholds can be adjusted for every nuclide and measurement mode specifically. The three measurement modes are the direct contamination measurement with only the NuCoMo-100 and the measurement of wipe tests and screening/ aerosol filters via the additional accessories. When plugged in, the software automatically recognizes the accessories and switches the menu accordingly.

The whole menu, measurement and calibration process is user guided. This allows to set numerous parameters, (de-)activate functionalities and use the integrated calibration menu by using only five function keys.

Applications & Uses

From modelling to implementation, we supply exclusive know-how and state-of-the art technologies in monitoring systems dedicated to the major fields of application: • RADIATION PROTECTION, • WASTE MANAGEMENT, • ENVIRONMENTAL MONITORING, • LABORATORIES, • HOMELAND SECURITY, • RADIATION MONITORING SYSTEMS, • GEOPHYSICS

Specifications

Detector

A phoswich detector together with an innovative algorithm. Each
scintillator of the phoswich has a different decay time constant allowing to perform Pulse Shape Discrimination (PSD) between the beta and gamma pulses. Hence this stateof-the-art detector enables to discriminate the γ-background and measure only the β-contamination on the surface by comparing signals from two different detector layers.

Operating Range

cps, Bq, and Bq/cm²

Energy Sensitivity

1Bq/cm² Co-60
MDA in a Co-60 background of 1 µSv/h

4 Bq/cm² Co-60
MDA in a Co-60 background of 40 µSv/h

13 %
Efficiency for Co-60 β emitter

MDA In a Co-60 background dose rate (DR) the minimal detectable activity of a Co60 contamination is given by the detection limit (DL) which can be approximated by the graph below:

Display

128×64 px backlit LC-Display

Alarms

Acoustic alarm: approx. 80 dB in 30cm
Optical alarm: LED ring (green, yellow, red) and LEDs in front panel
Vibration alarm in handle
2 adjustable alarm thresholds per unit

Output

USB interface

Nuclide Library

Freely programmable nuclide library Store up to 620 datasets

Power

Operation via Li-Ion-battery approx. 10 hours

Temperature range:

10-35°C

Weight

970 g







What Our Clients Say

Ron Ulbrich, Geiger Counter Pro

“The Radiation Alert Ranger® is a great value for those looking for a modern Geiger counter. I found that is simple to use yet includes many advanced functions if and when you want them without obstructing the simplicity…”

Judson Kenoyer, CHP, CIH

“I have used the Monitor 4 in courses that I teach radiation safety for close to 8 years. The students love it and affectionately call it the “Batman unit” because of its use in the movie The Dark Knight Rises. It is light-weight, sensitive, and quite often out performs some of the more expensive units from other companies that we use in a lab exercise…”

Neil Breslow, NDT Supply

“NDT Supply has been working with SE International since we started business in 2000. We have found them to be easy to work with, and a very reliable and responsive supplier. Questions and issues are always handled promptly and with a smile…”